Home/Advice/Electrical Safety Testing: A West Sussex Homeowner's Guide
Advice · West Sussex & West Sussex
Most people only think about their wiring when something trips or a socket starts feeling warm. A proper inspection tells you what condition your installation is actually in, before a fault becomes a fire or a failed house sale. Here is what the process involves, what the results mean and how to judge whether you need one.
The formal name is an Electrical Installation Condition Report, or EICR. An electrician switches off the supply, removes covers from your consumer unit, sockets and switches, then carries out a mix of visual checks and instrument tests. It is not a quick look round with a plug-in tester.
Expect the visit to take two to four hours for a typical three bedroom house, longer for older properties in places like Arundel or Steyning where wiring has often been extended piecemeal over decades. You will be without power for parts of it, so plan around freezers, home working and anyone who relies on medical equipment.
Reports come back satisfactory or unsatisfactory, and the wording matters more than the headline. A C1 means danger present and needs making safe the same day, typically exposed live parts. A C2 means potentially dangerous and must be fixed for the report to become satisfactory, for example no earthing to a metal light fitting or a bathroom circuit without RCD protection.
A C3 is 'improvement recommended' and does not fail the installation. Plenty of otherwise sound homes carry a handful of C3s, such as no RCD on a lighting circuit. If someone tells you every C3 must be rectified before they can sign off, that is a sales pitch, not a regulation. FI means further investigation is needed, usually because something could not be traced without lifting floors.
The usual guidance is every ten years for an owner occupied home, five years for rented property, and on change of occupancy. Private landlords in England have a legal duty under the 2020 regulations to have a report at least every five years and give tenants a copy within 28 days. Sussex coastal properties in Worthing, Littlehampton and Bognor sit in a salt laden atmosphere that corrodes external sockets, outside lights and garden supplies faster than inland, so shorter intervals on outdoor circuits are sensible.
As a guide, a two bedroom flat often falls in the £150 to £220 range and a four bedroom house £250 to £400, depending on the number of circuits and how accessible the consumer unit is. Remedial work is separate and quoted after the report. Be wary of a very cheap headline price paired with a long list of urgent repairs, and always ask whether the fee covers the full test schedule or only a sample of circuits.
Some symptoms warrant a call regardless of when your last report was done. Repeated tripping is the installation telling you something is wrong, not an inconvenience to be reset.
Published 15 August 2026
No. Those testers only confirm basic wiring at that socket and will miss serious faults including a borrowed neutral or high earth impedance. The instrument testing required involves disconnecting circuits and working on live equipment safely.
It confirms the installation was in acceptable condition on the day of testing, nothing more. Damage, DIY alterations or water ingress after that date will not be covered, which is why the recommended retest interval is printed on the report.
Usually not. Most unsatisfactory reports are resolved by targeted repairs such as adding RCD protection, replacing a damaged section of cable or correcting earthing, and a full rewire is normally only needed where the cabling itself has degraded throughout.
EICR, EV charger, fuse board, fire alarm or full installation. Call the office or send a few details and we will come back with a price.
Tell us about the job. We will come back with a price, or come out to take a look. EICRs, installations, EV chargers and fire alarm systems across West Sussex.